MonitorMagic automates the job of constantly monitoring business-critical
servers, for Windows systems ranging from NT4 to 2003 and non-Windows operating
systems such as UNIX, Linux and Novell.
|
| MonitorMagic also integrates with hardware providers such as HP
Insight Manager, Dell OpenManage and IBM
Director to support even greater monitoring
detail. As part of the monitoring job, MonitorMagic provides you with advanced
server statistics reports, showing various attributes ranging from uptime,
to event log details, to disk capacity statistics. |
| |
| Hardware
Monitoring |
 |
- MonitorMagic ships with pre-configured policies which
automatically detect and respond to possible hardware or
Operating System stability and performance issues.
- Integration
with hardware providers such as HP Insight Manager, Dell
OpenManage and IBM Director provides even
greater level of monitoring detail, for example cpu and
mainboard fan status, disk degredation and much more.
MonitorMagic includes pre-configured policies for these
hardware providers
which include the correct thresholds and alerts.
|
|
Integrates with APC PowerChute:
Monitores the following Windows events from the application log:
Administrative Shutdown Cancelled, Administrative Shutdown Pending, Battery
Needs Replacing, Communications Established, Lost Communication With UPS, Shutdown
In Progress, System Shutdown Starting, UPS On Battery, Utility Power Restored
Monitors the following SNMP get values:
- a2BatteryStatus (The indication of the capacity remaining
in the UPS system's batteries. (2=ok)) > 2
- upsAdvBatteryCapacity (The remaining battery capacity
expressed in percent of the full capacity.) < 100
- upsAdvBatteryReplaceIndicator (Indicates whether the
UPS batteries need replacing. (2=true)) = 2
- upsAdvBatteryTemperature (The current internal UPS temperature
expressed in Celcius.) > 50
|
Integrates with HP-Compaq Insight Manager:
Monitors the following SNMP get values:
- cpqHeAsrCondition (This value specifies the
overall condition of the ASR feature. (2=ok)) > 2
- cpqHeCorrMemLogCondition (This value specifies the overall
condition of the correctable memory error log feature. (2=ok)) > 2
- cpqHeFltTolFanCondition (The condition of the fan. (2=ok)) > 2
- cpqHeFltTolPwrSupplyCondition (This value specifies
the overall condition of the fault tolerant power supply sub-system.
(2=ok)) > 2
- cpqHeMibCondition (The overall system health condition.
(2=ok)) > 2
- cpqHeTemperatureCelsius (This is the current temperature
sensor reading in degrees.) > 50
- cpqHeThermalCondition (This value specifies the overall
condition of the system's thermal condition. (2=ok)) > 2
- cpqHeThermalCpuFanStatus (The status of the processor
fan(s) in the system. (2=ok)) > 2
- cpqHeThermalFanStatus (The status of the fan(s) in the
system. (2=ok)) > 2
- cpqHeThermalTempStatus (The status of the system's temperature
sensors. (2=ok)) > 2
- cpqNicIfPhysAdapterCondition (The condition of this
physical adapter (2=ok)) > 2
- cpqNicMibCondition (This object represents the overall
status of the network interface sub-system (2=ok)) > 2
- cpqTapeLibraryCondition (Compaq Tape Library Status.
(2=ok)) != 2
- cpqTapePhyDrvCondition (Compaq Tape Physical Drive
Cleaning Required Status. (2=true)) != 2
|
Integrates with Dell OpenManage:
Monitors the following SNMP get values:
- arrayDiskState (The current state of the array disk.
(1=ready, 3=online)) other than 1 and 3
- arrayMgrGlobalStatus (Global
health information for the subsystem
managed by Dell Array Manager software. (3=ok)) != 3
- coolingDeviceStatus (This attribute defines the probe status of the cooling device.
(3=ok)) != 3
- systemStateChassisIntrusionStatusCombined (This attribute
defines the intrusion reading of all intrusion detection devices
in the chassis. (3=ok)) != 3
- systemStateCoolingDeviceStatusCombined (This attribute defines the cooling device status of all cooling
devices in the
chassis. (3=ok))
!= 3
- systemStateEventLogStatus (This attribute defines
the overall status of the event log in the chassis. (3=ok))
!= 3
- systemStateGlobalSystemStatus (This attribute
defines the global system status of all chassis being monitored
by
the systems
management software.
(3=ok)) != 3
- systemStateMemoryDeviceStatusCombined (This attribute defines the memory device status of all memory
devices in the chassis.
(3=ok))
!= 3
- systemStateTemperatureStatusCombined (This
attribute defines the temperature status of all temperature
probes in the
chassis. (3=ok))
!= 3
- systemStateVoltageStatusCombined (This attribute
defines the voltage status of all voltage probes
in the chassis.
(3=ok))
!= 3
- temperatureProbeReading (This attribute
defines the reading of the temperature probe (1/10 degrees)) > 500
|
Integrates with IBM Director:
Monitors the following SNMP get values:
- iBMPSGFanStatus (Fan status (OK, Degraded and Pred
Fail are possible values)) not 'OK'
- iBMPSGLogicalNetworkAdapterStatus
(Logical NIC status (value should
be OK)) not 'OK'
- iBMPSGPowerSupplyStatus (Power supply status
(value should be OK)) not 'OK'
- iBMPSGTemperatureSensorCurrentReading
(Current temperature reading) > 40
- win32DiskDriveStatus (Disk
status (OK, Degraded and Pred Fail are possible values)) not
'OK'
|